Get a whole and prolonged watch from the anatomical construction through panoramic imaging coupled with velocity indication and ahead/backward scan skill earning scanning easier, smoother and much more controllable.
Information Method Check out the battery periodically : a) Check if battery could be charged Typically when electrical power-on: That The present ability is one hundred% or capability improves after a brief time implies the battery is often charged Generally.
Do not use any cables besides the cables offered Along with the machine by Mindray. three. Utilize the cable offered with this system to connect the printer. Other cables might cause electrical shock. Page fifteen: Mechanical Protection
The user is not really permitted to open the handles and panel with the program, neither Be aware: machine disassemble is permitted. To ensure the procedure effectiveness and security, only Mindray engineers or engineers authorized by Mindray can carry out servicing.
Permits usage of multiple scanned angles to variety only one image, leading to Increased contrast resolution and improved visualization
Slice off cable ties connecting the principle unit around the display by diagonal cutting pliers, then pull out the corresponding cable plugs.
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
S. need to provide the Division with an e mail handle if they've got 1. The e-mails supplied can be useful for official conversation With all the licensee. Having said that email addresses are community report. If you don't would like to produce a private handle, make sure you give the Section having an electronic mail address which can be created available to the public. To determine In case you are a licensee beneath Chapter 455, F.S., remember to Just click here . Products Approval Accepts:
This guide might referring to facts safeguarded by copyright or patents and would not convey any license under the patent rights or copyright of Mindray, or of Many others. Site 9: Statement
After successful relationship, the recently added community printer title will likely be shown in the printer driver record. Notice: Just before connect the community printer, be sure the ultrasound technique as well as the printer are in the exact same network area, plus the network is Performing Generally. The IP address as well as server name really should be legitimate, e.g. Website page forty seven DICOM Setting Enter the AE Title with the ultrasound method, port and PDU based on the precise predicament, and then click [Okay] to exit the display screen.
Notice: About the keep an eye on, the brightness adjustment will come right before distinction. Following readjusting the keep an eye on’s distinction and brightness, regulate all preset and peripheral settings.
NOTE: Ahead of inserting the connector in to the probe port, inspect the connector pin. In the event the pin is bent, will not utilize the probe right up until it's been inspected / repaired / replaced. Putting in Peripherals For the types in the supported peripherals, you should check with “two.
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Performance Exam five.five.1 Check Course of action Resolution Detection depth Geometric Position Accuracy Blackout area exam File the Test illustrations or photos 5.5.2 Take a look at Written content The image used Here's just for reference, follow the graphic effect in the true Take note: predicament. Prerequisites: Show: set the contrast and brightness in the clinical software value (or even the default standing) Operation natural environment: dim home, simulating the scientific software environment. Web page 76 In problem that the transverse resolution testing targets are horizontally displayed, history the minimal length of two targets that can be clearly recognized. Repeat the Procedure above for that transverse resolution screening targets at other depths. As proven in figure down below. Axial resolution ... Web site seventy seven When utilizing the convex probe, maintain the transverse resolution tests targets to NOTE: be shown close to the midline. When using a linear probe with Dp50rb steer purpose, never turn on the steer function when perform the transverse resolution test. Zoom from the region where the targets Situated if needed. The diameter on the target position at a specific depth is equivalent to your transverse resolution on the depth. Web site 78 5.
A smart new condition, enhanced mobility and effortless operation make DP-50 well matched for all clinical configurations.
Be aware: Be sure that you could pull out and thrust into the IO board sockets vertically when pulling out and assembling the IO board assembly over the place of your manage. Take out panhead screws with washers M3X6 (four) used to safe the IO board, after which you can you might take out the IO board. Webpage 116 Clear away panhead screws with washers (2 M3X6) which might be fastened on the primary unit, consider out the higher baffle and after that pull out two cables connecting the leading board to the ability module assembly.